TD thermal degasser
CE-marked degasser designed to EN 13445 that strips O₂ and CO₂ from boiler feedwater by heating it with steam
TSB Energy · TD
- 1 … 50 t/h
- 102 °C (pressurised type)
- Ex zone 1 (optional)
- EN 13445 · 2014/68/EU
Dissolved O₂ and CO₂ in feedwater corrode boiler walls, steam piping and the machines that run on steam. In the TD, a spray nozzle breaks the feedwater into fine droplets that mix with steam and heat up to saturation; CO₂ leaves the water at around 60 °C and O₂ above 100 °C. The water then enters a stainless mixing chamber made of two concentric perforated shells, where rising steam scrubs it a second time, and the released gases are vented through the gas outlet valve. A thermostatic valve on the lower vessel holds the temperature at 102 °C, which prevents thermal shock.
TSB builds two modern types, both handling 1–50 t/h without the degasser having to be mounted high up. In the pressurised type, degasser and condensate tank share a single tank at floor level; feedwater is atomised under pressure and heated to 102 °C by low-pressure steam, with a degassing efficiency of 96–100 %. Because the system is closed to atmosphere, no flash steam escapes; condensate lines see a back pressure of around 0.5 atm (gauge), and the tank is designed for 3 bar. The atmospheric type serves open condensate systems: water is kept at 90 °C, flash steam and steam escaping from traps are put to use, and degassing efficiency is 90–95 %.
A classic degasser has to stand at least 4 m above the pumps to avoid cavitation, which calls for boiler houses 7–8 m high and steel support structures; the modern types remove that cost. Shell and dished ends are P355GH plate to EN 10028-2, nozzle tubes P235GH or P265GH, the degasser dome AISI304 and the cascade plates AISI316 stainless steel. The PLC supervises staged water level safeguards, steam temperature and emergency shutdown, and pressure is set according to site altitude to avoid needless energy loss. On request, a version certified to ATEX for Ex zone 1 is built.
TD thermal degasser
- Removes O₂ and CO₂, protecting the boiler, steam piping and steam-using equipment from corrosion
- Floor-standing: no tall boiler house or steel support structure needed
- Pressurised type: 96–100 % degassing efficiency and no flash steam loss in a closed circuit
- Combined degasser and condensate tank lowers tank costs
- Low operating pressure means simple maintenance and economical installation
- Pressure set to site altitude for the right steam input; water side accessible through an inspection cover
- Optional ATEX version for Ex zone 1
- Remote monitoring via Modbus, Modbus TCP/IP and Profinet
Key specifications
| Specification | TD |
|---|---|
| Capacity | 1 … 50 t/h |
| Operating temperature | 102 °C (pressurised type) · 90 °C (atmospheric type) |
| Degassing efficiency | 96 … 100 % (pressurised type) · 90 … 95 % (atmospheric type) |
| Design pressure | 3 bar (pressurised type) |
| Material | P355GH (shell) · AISI304 (degasser dome) · AISI316 (cascade plates) |
| Explosion protection (Ex) | Ex zone 1 · ATEX (optional) |
| Interfaces | Modbus · Modbus TCP/IP · Profinet |
Approvals and standards
- CE declaration of conformity — 2014/68/EU (pressure equipment)
- EN 13445 — unfired pressure vessels (design and manufacture)
- TRD — German technical rules for steam boilers
- ASME VIII Div. 1 — pressure vessels (design and manufacture)
- ATEX — Ex zone 1 (optional Ex version)
Accessories
- Water treatment systems and water analysis
- Feedwater tank
- Flash steam tank for heat recovery
- Piping systems
- PLC supporting communication protocols such as Modbus and Profibus
More products in this group
Three-pass steam boiler
Scotch-type fire-tube boiler for industry: up to 30 000 kg/h of steam at pressures up to 25 bar
- ≤ 30 000 kg/h
- ≤ 21 000 kW
- ≤ 25 bar
Water-tube steam boiler
Low-water-content boiler that raises steam in 10–15 minutes: up to 80 000 kg/h of steam at up to 160 bar
- ≤ 80 000 kg/h
- ≤ 160 bar
- Efficiency ≥ 95 %
Mobile steam boiler room
Complete steam boiler house in a 20 ft or 40 ft ISO container, factory-tested and ready to connect
- ≤ 6000 kg/h
- ≤ 16 bar
- ISO 20 ft / 40 ft
Liquid and gas-fired thermal oil heater
Forced-circulation coil heater that brings thermal oil up to 420 °C in a closed loop (special equipment above 300 °C)
- ≤ 420 °C (special equipment > 300 °C)
- ≤ 12 000 kW
- ≤ 25 bar
Let's choose the right product for your project together
Tell us about your plant and what you need, and our engineers will recommend the right solution.