SVA / SVH / SVHT flue gas and air damper
DN40…DN200 flue gas and air dampers: aluminium up to 100 °C, cast iron up to 450 °C, stainless steel up to 650 °C
LAMTEC · SVA (668M2200) · SVH (668M2205) · SVHT (668M2210)
- Flue gas / air
- DN40 … DN200
- ≤ 100 / ≤ 450 / ≤ 650 °C
- ≤ 500 mbar
SVA, SVH and SVHT are wafer-type butterfly dampers clamped between two flanges; together with an actuator, they act as the final control element for the flow of flue gas and intake air in combustion plants. The three types differ in housing material and temperature limit: the aluminium SVA (668M2200) is rated for a medium temperature of -20…+100 °C and the cast iron SVH (668M2205) for -20…+450 °C, while the stainless steel SVHT (668M2210) is ordered as a -20…+100 °C, -20…+450 °C or -20…+650 °C version. The 450 °C versions have a 100 mm temperature barrier, the 650 °C version a 200 mm one. In every type, the shaft and disc are made of stainless steel.
Nominal sizes are DN40, DN50, DN65, DN80, DN100, DN125, DN150 and DN200. Above DN200, type 662R22V takes the place of SVA and SVH, while larger SVHT sizes are available on request. The aluminium and stainless steel dampers can be ordered reduced by up to two nominal sizes and with an optional tight-closing disc; the cast iron SVH is supplied without reduction and with the standard disc only. The standard disc leaks approx. 1 % of the Kvs value. The flow characteristic is non-linear, and the operating pressure is limited to 500 mbar.
The 11.1 × 11.1 × 11.5 mm square shaft end fits straight into the internal square socket (IVK11) of the LAMTEC 668M2006, 668M2020 and 668M2040 actuators; the bracket is integrated into the damper, and fixing material as well as mounting sleeves for PN10…PN40 flanges are supplied. As the damper has no position indicator, LAMTEC recommends an actuator that has one; a manual version with a continuously adjustable locking lever can also be ordered. The CE declaration of conformity refers to the Pressure Equipment Directive 2014/68/EU; these dampers have no DVGW approval.
SVA / SVH / SVHT flue gas and air damper
- Three housing materials: aluminium (SVA), cast iron (SVH) and stainless steel (SVHT)
- Medium temperature up to 100 °C for SVA, up to 450 °C for SVH and, depending on the version, up to 100 °C, up to 450 °C or up to 650 °C for SVHT
- Nominal sizes DN40…DN200, operating pressure up to 500 mbar
- Fits the 668M2006, 668M2020 and 668M2040 actuators directly, without extra mounting parts
- Optional tight-closing disc and reduction by up to two nominal sizes for SVA and SVHT
- Clamped between PN6…PN40 flanges; mounting sleeves and fixing material supplied
- Mounting options for other shaft shapes and an optional manual adjustment lever
Key specifications
| Specification | SVA (668M2200) | SVH (668M2205) | SVHT (668M2210) |
|---|---|---|---|
| Nominal size | DN40 · DN50 · DN65 · DN80 · DN100 · DN125 · DN150 · DN200 | DN40 · DN50 · DN65 · DN80 · DN100 · DN125 · DN150 · DN200 | DN40 · DN50 · DN65 · DN80 · DN100 · DN125 · DN150 · DN200 |
| Max. pressure | 500 mbar | 500 mbar | 500 mbar |
| Medium temperature | -20 … +100 °C | -20 … +450 °C | -20 … +100 °C · -20 … +450 °C · -20 … +650 °C |
| Medium | Flue gas / air | Flue gas / air | Flue gas / air |
| Flow characteristic | Non-linear | Non-linear | Non-linear |
| Leakage | ≈ 1 % Kvs (standard version) · tight-closing disc (optional) | ≈ 1 % Kvs | ≈ 1 % Kvs (standard version) · tight-closing disc (optional) |
| Material | Aluminium (housing) · Stainless steel (shaft and disc) | Cast iron (housing) · Stainless steel (shaft and disc) | Stainless steel (housing, shaft and disc) |
| Installation | Clamped between flanges (PN6 … PN40) | Clamped between flanges (PN6 … PN40) | Clamped between flanges (PN6 … PN40) |
| Shaft end | 11.1 × 11.1 × 11.5 mm (square) | 11.1 × 11.1 × 11.5 mm (square) | 11.1 × 11.1 × 11.5 mm (square) |
| Used with | 668M2006 · 668M2020 · 668M2040 | 668M2006 · 668M2020 · 668M2040 | 668M2006 · 668M2020 · 668M2040 |
Approvals and standards
- CE declaration of conformity — 2014/68/EU (pressure equipment)
More products in this group
CMS combustion management system
Modular burner and plant control that scales from small industrial burners to large installations
- SIL3 · CE · UL
- ≤ 10 actuators
- Modbus TCP
BT300 burner control unit
Compact burner-mounted unit that pairs fuel-air ratio control with a burner sequencer
- ≤ 3 actuators
- Burner-mounted
- SIL3 (BT331, BT341)
MCC-BC400 burner sequencer
Configurable burner sequencer for gas-fired, oil-fired and dual-fuel burners
- SIL3 · CE · UL
- Gas · Oil · Dual fuel
- Modbus TCP
BC300 gas burner sequencer
Burner sequencer for industrial gas burners in thermal process plants, approved for intermittent and continuous operation
- SIL3 · CE
- Intermittent · Continuous
- High-temperature operation > 750 °C
Let's choose the right product for your project together
Tell us about your plant and what you need, and our engineers will recommend the right solution.